SwitchBlade x8106 Chassis Switch and AT-SBx81CFC960 Card Installation Guide
Section III: Building a Stack with VCStack Plus 265
Cabling Configurations for the Stacking Transceivers
This section illustrates the cabling configurations for the stacking
transceivers.
One Controller
Card Per Chassis
Figure 163 illustrates the correct wiring configuration for the fiber optic
wires for the stacking transceivers when each chassis has only one AT-
SBx81CFC960 Controller Fabric Card. The transceiver in SFP+ slot 1 in
one controller card is connected to the transceiver in SFP+ slot 1 in the
card in the other chassis, the transceiver in SFP+ slot 2 is connected to the
transceiver in SFP+ slot 2 in the other chassis, and so on.
Figure 163. Cabling the Stacking Transceivers When Both Switches have
One Controller Card
Please note the following:
The trunk has a bandwidth of 40Gbps when each chassis has one
controller card and the trunk has four links.
The switches will form the stack if the transceivers are cabled
incorrectly such that the wires between transceivers crossover
(e.g., the transceiver in SFP+ slots 1 is connected to the
transceiver in SFP+ slot 2). However, the bandwidth of the trunk is
reduced.