User Guidelines
There are no user guidelines for this command.
Example
The following example enables inline power traps to be sent when a power usage threshold is exceeded.
show power inline
The show power inline User EXEC mode command displays the information about inline power.
Syntax
show power inline [ethernet interface]
Parameters
interface — Valid Ethernet port. (Full syntax: unit/port)
Default Configuration
This command has no default configuration.
Command Mode
User EXEC mode
User Guidelines
There are no user guidelines for this command.
Example
The following example displays information about inline power..
console(config)# power inline traps enable
console>
show power inline
Power: On
Nominal Power: 150 Watt
Consumed Power: 120 Watts (80%)
Usage Threshold: 95%
Traps: Enabled
Port Powered Device State Priority Status Classification [w]
---- ---------------- ----- -------- ------ -----------------
1/e1 IP Phone Model A Auto High On 0.44 - 12.95
2/e1 Wireless AP Model Auto Low On 0.44 - 3.84