33
Maximum
Distance
The ports have a maximum operating distance of 100 meters (328 feet).
Cable
Requirements
The cable requirements for the ports on the AT-SBx81GT24 and AT-
SBx81GT40 Line Cards are listed in Table 1.
Note
Patch cables for the AT-SBx81GT40 Line Card, in lengths of 1 meter
and 3 meters with RJ point 5 and RJ-45 connectors, are available
from Allied Telesis. Contact your Allied Telesis sales representative
for information.
The cable requirements for the PoE ports on the AT-SBx81GP24 Ethernet
Line Card are given in Table 2 on page 34.
Table 1. Twisted Pair Cable for the AT-SBx81GT24 and AT-SBx81GT40
Line Cards
Cable Type 10Mbps 100Mbps 1000Mbps
Standard TIA/EIA 568-B-
compliant Category 3 shielded
or unshielded cabling with 100
ohm impedance and a
frequency of 16 MHz.
Yes Yes No
Standard TIA/EIA 568-A-
compliant Category 5 or TIA/
EIA 568-B-compliant Enhanced
Category 5 (Cat 5e) shielded or
unshielded cabling with 100
ohm impedance and a
frequency of 100 MHz.
Yes Yes Yes
Standard TIA/EIA 568-B-
compliant Category 6 or 6a
shielded cabling.
Yes Yes Yes