613-001498 Rev. BAT-RPS3000Redundant Power Supply AT-RPS3000 AT-PWR250 AT-PWR800 AT-PWR1200Installation Guide2179
Tables10
11PrefaceThis guide contains the installation instructions for the AT-RPS3000 Chassis. The chassis is a modular power supply system for the x610 Serie
Preface12Document ConventionsThis document uses the following conventions:NoteNotes provide additional information.CautionCautions inform you that per
AT-RPS3000 Redundant Power Supply Installation Guide13Where to Find Web-based GuidesThe installation and user guides for all of the Allied Telesis pro
Preface14Contacting Allied TelesisThis section provides Allied Telesis contact information for technical support and for sales and corporate informati
15Chapter 1 OverviewThis chapter contains the following sections: “Features” on page 16 “Power Supply Modules” on page 19 “System Power and Power f
Chapter 1: Overview16FeaturesThe AT-RPS3000 Chassis is a modular power supply system for the x610 Series of Layer 3 Gigabit Ethernet switches. It prot
AT-RPS3000 Redundant Power Supply Installation Guide17Power SupplySlotsThe slots on the back panel of the chassis are for two power supply modules. Th
Chapter 1: Overview18RPS 3 and 4 ports obtain power from the power supply module in slot B.Figure 4. Slot B and RPS 3 and 4 PortsThe ports are labeled
AT-RPS3000 Redundant Power Supply Installation Guide19Power Supply ModulesThis table lists the power supply modules that are currently available for t
Copyright 2011 Allied Telesis, Inc.All rights reserved. No part of this publication may be reproduced without prior written permission from Allied T
Chapter 1: Overview20The power supply modules for the AT-RPS3000 Chassis and PoE+ x610 Series switches must be purchased separately. Non-PoE+ x610 Ser
AT-RPS3000 Redundant Power Supply Installation Guide21System Power and Power for PoE+Although the product name contains the acronym “RPS,” which stand
Chapter 1: Overview22Figure 6. Removable and Non-removable Power Supply Modules in x610 SwitchesTo summarize, a non-PoE+ x610 Series switch uses the A
AT-RPS3000 Redundant Power Supply Installation Guide23PoE+ power is different in that the power supplies in the switch and chassis do use load-sharing
Chapter 1: Overview24Low-power and High-power SwitchesThe x610 Series switches are grouped into two categories of system power, which, as explained ea
AT-RPS3000 Redundant Power Supply Installation Guide25Configuration ExamplesThe following examples illustrate different configurations of the chassis,
Chapter 1: Overview26Figure 8. Example of a Non-PoE+, Low-power Switch Connected to an RPS PoE+/System PortThis example illustrates how a power supply
AT-RPS3000 Redundant Power Supply Installation Guide27The chassis must have a second power supply to support three or four low-power switches, as illu
Chapter 1: Overview28High-powerSwitchesThe power supply modules can support just one high-power switch at a time. In the example in Figure 11 on page
AT-RPS3000 Redundant Power Supply Installation Guide29Figure 12. Example of Two High-power Switches on the System PortsYou may use either the System o
3Electrical Safety and Emissions StandardsThis product meets the following standards.RFI Emissions FCC Class A, EN55022 Class A, EN61000-3-2, EN61000-
Chapter 1: Overview30PoE+ Switches Here is an example of the AT-RPS3000 Chassis supporting a single PoE+ switch, the AT-x610-24Ts/X-POE+ Switch. Notic
AT-RPS3000 Redundant Power Supply Installation Guide31Figure 15. Example of Two PoE+ SwitchesIn Figure 16 on page 32, two low-power switches are suppo
Chapter 1: Overview32Figure 16. Example of Low-power PoE+ and Non-PoE+ SwitchesThe AT-PWR800 or AT-PWR1200 Module in slot A is performing three functi
AT-RPS3000 Redundant Power Supply Installation Guide33Figure 17. Example of Low-power PoE+ and Non-PoE+ SwitchesInvalidConfigurationsHere are examples
Chapter 1: Overview34Figure 18. Example of an Invalid Configuration - AIn the example in Figure 19 on page 35, the power supply in slot A is supportin
AT-RPS3000 Redundant Power Supply Installation Guide35Figure 19. Example of an Invalid Configuration - BBB1234SYSTEMPoE+ / SYSTEM PoE+ / SYSTEMSYSTEMM
Chapter 1: Overview36Choosing a Power Supply ModuleHere are a few suggestions on how to choose the power supply modules for the x610 Series switches a
AT-RPS3000 Redundant Power Supply Installation Guide37PoE+ Switches The PoE+ switches do not come with power supplies. You must purchase them separate
Chapter 1: Overview38Figure 22. Two AT-PWR800 Modules for 480 to 960 Watts, with Limited RedundancyAnother approach to dealing with a PoE+ switch that
AT-RPS3000 Redundant Power Supply Installation Guide39Two AT-PWR1200 Modules may be used for amounts above 780 watts, up to 1560 watts, but there is n
4Translated Safety StatementsImportant: The indicates that translations of the safety statement are available in the PDF document “Translated Safety
Chapter 1: Overview40Figure 25. Example of x610 Series Switches and AT-RPS3000 Chassis with Different Power Supply ModulesPower ModuleCombinations for
AT-RPS3000 Redundant Power Supply Installation Guide413 AT-PWR800 -- None 0 to 480 watts No4 AT-PWR800 AT-PWR250 None 0 to 480 watts Yes5 AT-PWR800 AT
Chapter 1: Overview42LEDsOn the front panel of the AT-RPS3000 Chassis is an LED panel that displays status information about the power supply modules
AT-RPS3000 Redundant Power Supply Installation Guide43The LEDs in the Module B Ports section provide information you may use to monitor RPS ports 3 an
Chapter 1: Overview44Power ModuleStatus LEDsFor general status information about the power supply modules, refer to the FAN and DC OUT LEDs in the Pow
AT-RPS3000 Redundant Power Supply Installation Guide45Table 7 describes the Power Module Status LEDs.Table 7. Power Module Status LEDsLED State Descr
Chapter 1: Overview46Power ModuleLEDThe power modules have a DC OUT/FAULT LED, shown in Figure 30 on page 46, that displays the same information as th
AT-RPS3000 Redundant Power Supply Installation Guide47On/Off Power SwitchesThe LED panel has On/Off switches that control the RPS ports. You may use t
Chapter 1: Overview48GuidelinesHere is a summary of the rules and guidelines discussed in this chapter:CautionThe AT-RPS3000 Chassis is designed speci
49Chapter 2Installing the AT-RPS3000 Chassis and Power Supply ModulesHere are the installation procedures for the AT-RPS3000 Chassis: “Reviewing Safe
5Preface ...
Chapter 2: Installing the AT-RPS3000 Chassis and Power Supply Modules50Reviewing Safety PrecautionsPlease review the following safety precautions befo
AT-RPS3000 Redundant Power Supply Installation Guide51Circuit Overloading: Consideration should be given to the connection of the equipment to the sup
Chapter 2: Installing the AT-RPS3000 Chassis and Power Supply Modules52Planning the InstallationObserve these requirements when planning the installat
AT-RPS3000 Redundant Power Supply Installation Guide53 Do not expose the chassis to moisture or water. Make sure the site is a dust-free environment
Chapter 2: Installing the AT-RPS3000 Chassis and Power Supply Modules54Unpacking the AT-RPS3000 Chassis and Power Supply ModulesRefer to the tables in
AT-RPS3000 Redundant Power Supply Installation Guide55NoteThe AT-RPS3000 Chassis is connected to an x610 Series switch with the AT-RPS-CBL1.0 cable. T
Chapter 2: Installing the AT-RPS3000 Chassis and Power Supply Modules56NoteThe power cord that comes with the AT-PWR1200 Power Supply Module for insta
AT-RPS3000 Redundant Power Supply Installation Guide57Selecting a Location for the AT-RPS3000 Chassis in the Equipment RackThe AT-RPS3000 Chassis has
Chapter 2: Installing the AT-RPS3000 Chassis and Power Supply Modules58Installing the AT-RPS3000 Chassis in an Equipment RackPerform this procedure to
AT-RPS3000 Redundant Power Supply Installation Guide593. Turn the chassis over.4. Using a cross-head screwdriver, secure the two rack mount brackets t
Contents6Installing the AT-RPS3000 Chassis in an Equipment Rack...58Install
Chapter 2: Installing the AT-RPS3000 Chassis and Power Supply Modules60NoteThe chassis and x610 Series switches must be within one meter of each other
AT-RPS3000 Redundant Power Supply Installation Guide61Installing a Power Supply ModuleTo install a power supply unit module in the chassis, perform th
Chapter 2: Installing the AT-RPS3000 Chassis and Power Supply Modules62Figure 40. Installing a Power Supply ModuleCautionDo not connect the power cord
AT-RPS3000 Redundant Power Supply Installation Guide633. Secure the module to the chassis by tightening the two captive screws.Figure 41. Securing a P
Chapter 2: Installing the AT-RPS3000 Chassis and Power Supply Modules646. If the unit is to have only one power supply module, cover the empty slot wi
AT-RPS3000 Redundant Power Supply Installation Guide65Connecting the AT-RPS3000 Chassis to the x610 Series SwitchPerform this procedure to connect the
Chapter 2: Installing the AT-RPS3000 Chassis and Power Supply Modules662. Secure the cable to the switch by tightening the two thumbscrews.Figure 46.
AT-RPS3000 Redundant Power Supply Installation Guide674. Connect the AT-RPS-CBL1.0 cable to the designated RPS port on the back panel of the AT-RPS300
Chapter 2: Installing the AT-RPS3000 Chassis and Power Supply Modules685. Secure the cable to the port by tightening the two thumbscrews.Figure 49. Se
AT-RPS3000 Redundant Power Supply Installation Guide69Powering On the Power Supply ModulesPerform this procedure to power on the power supply modules
7FiguresFigure 1: LED Panel ...
Chapter 2: Installing the AT-RPS3000 Chassis and Power Supply Modules70Figure 51. Connecting the AC Power Cord3. For the AT-PWR250 or AT-PWR800 Module
AT-RPS3000 Redundant Power Supply Installation Guide715. Examine the DC OUT/FAULT LED on the power supply module. The module is operating normally if
Chapter 2: Installing the AT-RPS3000 Chassis and Power Supply Modules72Figure 54. Checking the FAN and DC OUT LEDs in the LED Panel7. In the MODULE A/
AT-RPS3000 Redundant Power Supply Installation Guide73Figure 55. Checking the LOAD and CABLE LEDs in the LED PanelBB1234SYSTEMPoE+ / SYSTEM PoE+ / SYS
Chapter 2: Installing the AT-RPS3000 Chassis and Power Supply Modules748. If the chassis has two power supply modules, repeat this procedure to power
75Chapter 3Removing Power Supply ModulesHere are the procedures for removing power supply modules from the AT-RPS3000 Chassis: “Removing the AT-RPS-C
Chapter 3: Removing Power Supply Modules76Removing the AT-RPS-CBL1.0 CableHere are the steps to removing the AT-RPS-CBL1.0 cable from an RPS port on t
AT-RPS3000 Redundant Power Supply Installation Guide773. Remove the cable from the RPS port.CautionBe sure to remove the RPS cable squarely and evenly
Chapter 3: Removing Power Supply Modules78Removing an AC Power Supply ModuleTo remove an AC power supply module from the chassis, perform this procedu
AT-RPS3000 Redundant Power Supply Installation Guide792. Disconnect the power cord from the power supply module.Figure 59. Removing the Power CordCaut
Figures8Figure 50: Raising the Power Cord Retaining Clip ...
Chapter 3: Removing Power Supply Modules803. Loosen the two captive screws securing the power module to the chassis.Figure 60. Loosening the Two Capti
AT-RPS3000 Redundant Power Supply Installation Guide816. If you are not replacing the module, cover the empty slot with one of the slot covers, labele
Chapter 3: Removing Power Supply Modules82
83Chapter 4TroubleshootingIf you encounter a problem with the product, you may be able to resolve it with the information in this chapter:Problem 1: A
Chapter 4: Troubleshooting84❒ Verify that the power from the power source is within the operating specifications of the power supply module, listed in
AT-RPS3000 Redundant Power Supply Installation Guide85❒ Verify that the power supply module that is suppose to be delivering the PoE+ power from the c
Chapter 4: Troubleshooting86
87Appendix ATechnical SpecificationsPhysical SpecificationsDimensions (H x W x D):AT-RPS3000 Chassis 4.4 cm x 44.1 cm x 36.3 cm(1.7 in. x 17.4 in. x 1
Appendix A: Technical Specifications88Power SpecificationsMaximum Power Consumption:AT-PWR250 Module (AC) 250 wattsAT-PWR800 Module (AC) 800 wattsAT-P
AT-RPS3000 Redundant Power Supply Installation Guide89Port Pin-outsFigure 64 identifies the pins on the RPS ports.Figure 64. Port Pin-outs for the RSP
9TablesTable 1: Power Supply Modules ...
Appendix A: Technical Specifications90Table 12 lists the pin signals for the RPS 2 and 4 PoE+/System ports.13 Reserved14 Reserved15 Switch present16 R
AT-RPS3000 Redundant Power Supply Installation Guide9117 PoE+ negative remote senseTable 12. RPS 2 and 4 PoE+/System PortsPin Description
Appendix A: Technical Specifications92