12. Port Management - non-iMAP Devices Support of CWMP with TR-069 Devices
439
AlliedView NMS Administration Guide
Note: The port number has changed; in SP3 this was 9090.
• Inform Interval - How often (in seconds) the CPE contacts the ACS with identification information. The default is 300
(five minutes).
• ACS User and Password - The User ID and password to access the ACS server. The CPE uses this to communicate with
the ACS.
• CPE User and Password - User ID and password to access the CPE. The NMS uses this to communicate with the CPE.
• Config File Name - The name of the configuration file on the TFTP server that includes the values selected here.
• Save Only - If checked, the settings for the configuration file are saved but are not uploaded to the CPE (there is no
physical connection between the ACS and CPE).
12.6.6 Staging - Summary
As explained in 12.6.4, there is a staging procedure needed for the Comtrend devices so that they may be provisioned.
Staging can be accomplished using one of the following two methods summarized below:
• Method 1
Run the Comtrend Boot Configurator at the NMS server. Check the Save Only checkbox before clicking OK. Then copy
the configuration file to a PC connected to a LAN port on the Comtrend. Use the web GUI on the Comtrend to update
settings with the configuration file.
• Method 2
Install and run the NMS server software on a PC connected to a LAN port on the Comtrend. You must run the NMS
server software so the TFTP server is running. Run the Comtrend Boot Configurator at this PC. Do not check the Save
Only checkbox before clicking OK.
Note: The Comtrend could be connected to the NMS server that is used to manage the network. However, since this would allow
access to the network devices, this is not recommended.
12.6.7 Staging - Method 1
• Prerequisites
• The Comtrend is set to factory defaults.
• A PC is connected to a LAN port on the Comtrend device. The PC obtains an IP address automatically from the
Comtrend.
1. At the NMS server, access the Comtrend Boot Configurator by going to <NMS_Home>/bin and double-clicking on
AT_CTBootConfigurator.
2. On the Comtrend Boot Configurator Form (Figure 5-204), the only fields that must be filled in are:
• Mgmt. VLAN
• ACS URL
Note: For a description of these and other fields, refer to Figure 12.6.5.
3. Check the Save Only checkbox. Click on OK.
4. Go to <NMS_Home>/tftp/Comtrend and locate the configuration file, for example ct_backupconfig.conf. Copy
the configuration file to a PC connected to a LAN port of the Comtrend.
5. At the PC connected to the Comtrend, open a web browser and go to http://192.168.1.1/ to access the Comtrend web
GUI. Log in with User Name root, and Password 12345. In the GUI sidebar, select Management > Settings > Update. The
Tools - Update Settings page opens as shown in Figure 12-19.