12. Port Management - non-iMAP Devices Single-End Line Testing (SELT)
433
AlliedView NMS Administration Guide
For accurate results, loops up to 9000 feet can be tested. Using the FULL options allows loops up to 12,000 feet can be
tested. Limits are as follows:
Annex B support is limited to 24 AWG loops. 26 AWG wiring is not supported and will produce erroneous results
The port/interface to be tested must be in operationally down: UP-DN-Failed. The state life-cycle for the port/interface
under test will be: UP-DN-Failed to start the test, UP-DN-In Test for the duration of the test and will be transitioned back
to UP-DN-Failed once testing has completed.
Refer to the iMAP User Guide for details on SELT testing.
12.4.2 Accessing SELT
From the Port Management application select an active ADSL port one of the supported card types. Select the ADSL
Configuration tab, then the Diagnostics tab. If the tab is not present then the port does not support SELT. Then select the
SELT tab, as shown in the following figure. If there is existing data from a previous SELT the fields are populated and the
SELT Graph tab will be active. If there was no previous SELT the SELT Graph tab will be inactive and grayed out.
To run SELT, select the Run SELT Test button. A panel appears with the options for the test. Refer to the following figure.
FIGURE 12-13 Running the SELT Test
Select OK, and the test will begin. As it goes through testing, the state will change, until the test is complete and with a status
of Success. Refer to the following figure.