12. Port Management - non-iMAP Devices Single-End Line Testing (SELT)
432
AlliedView NMS Administration Guide
12.3.8 Graphed Parameters
Subcarriers - The same values are available for both upstream and downstream directions. Depending on the type of
port and actual mode of operation different subcarrier counts are used. The following table describes the possible values
Bit Loading - Bits allocated per sub channel. Range is 0 to 15.
Gain - Range is 0 - 4093/512.
Quiet Line Noise - Noise on quite line. Range is -150 to -23 db/MHz.
Signal/Noise Margin - The signal-to-noise ratio margin per band is the maximum increase in dB of the noise power
received at the xTU-R, such that the BER requirements are met for all bearer channels. The range is from -64 dB to +63
dB with 0.1 dB steps.
Hlog(f) - The log of the characteristic function
H(f) Imaginary - The imaginary component of the characteristic function.
H(f) Real - The real component of the characteristic function.
H(f) Amplitude - The amplitude of the characteristic function. This is computed from the real and imaginary components.
Amp = sqrt( r*r + i*i) where r is the real component and i the imaginary component.
H(f) Phase - The phase of the characteristic function. This is computed from the real and imaginary components. Phase =
atan( i/r ) where r is the real component and i the imaginary component.
12.4 Single-End Line Testing (SELT)
12.4.1 Overview of SELT
SELT is a method for testing a DSL loop that is not terminated at the CPE. These tests provide for the loop information on
the length, the presence of open or short circuits, and estimates of pre-service capacity.
SELT testing is usually done in the following scenarios:
Pre-CPE Installation - The loop exists, but not at the CPE. SELT can test the line for physical bridge and loop taps.
Pre-CPE Activation - SELT can characterize the loop and measure loop noise. The information can be used to determine
maximum rates.
Post Activation - If there is a problem, the characterization of the loop can be compared to the results of the pre-CPE
activation to see if there are any changes.
This feature works with the xDSL family (ADSL24A, ADSL24B, ADSL24SA, ADSL24AE, ADSL48A, and ADSL48B) of cards.
(VDSL cards will be supported in a future release.)
SELT sessions are limited to a single session at a time due to the amount of time (up to four minutes) each test can take to
complete and the resources needed to execute the test.
TABLE 12-3 Values for Subcarriers
Card Types Actual Standard Actual Annex Upstream Carriers Downstream Carriers
VDSL24A, VDSL24B 512 512
ADSL24A/B, ADSL24AE
ADSL48A, ADSL48B,
ADSL2, ADSL2M ANNEXB,
ANNEXM
64 256
others 32 256
ADSL2+
ADSL2+M
ANNEXB,
ANNEXM
64 512
32 512