AT-S63 Management Software Command Line Interface User’s Guide
107
DISABLE SWITCH PORT FLOW
Syntax
disable switch port=
port
flow=pause
Parameter
port Specifies the port where you want to deactivate flow
control. You can specify more than one port at a time.
You can specify the ports individually (for example,
5,7,22), as a range (for example, 18-23), or both (for
example, 1,5,14-22).
Description
This command deactivates flow control on a port. Flow control only
applies to ports operating in full duplex mode. This command performs
the same function as the
flowcontrol=disabled option in the SET
SWITCH PORT command.
Example
The following command deactivates flow control on port 6:
disable switch port=6 flow=pause