AT-VIEW PLUS AMIGO USER’S GUIDE PN 613-50662-00 Rev A Page 1 of 43
Allied Telesyn AT-VIEW PLUS AMIGO 2.1.7 Security Level If you specified 3 (SNMPv3) for the SNMP Version, you must also specify a Security Level that
Allied Telesyn AT-VIEW PLUS AMIGO 2.1.10 Privacy Protocol If you specified 3 (SNMPv3) for the SNMP Version, and your Security Level is authPriv, then
Allied Telesyn AT-VIEW PLUS AMIGO Parameters can be written in a file. You can specify the file from which AMIGO is to read the parameters. The param
Allied Telesyn AT-VIEW PLUS AMIGO 2.2 Configuring AMIGO AMIGO's general configuration can be changed from the File > Property menu. This inc
Allied Telesyn AT-VIEW PLUS AMIGO 2.3 Starting From AT-View Plus Device Manager You can start AMIGO from AT-View Plus Device Manager by clicking on
Allied Telesyn AT-VIEW PLUS AMIGO 3 Main Window The three panels in AMIGO's main window display related information about the SNMP agents and M
Allied Telesyn AT-VIEW PLUS AMIGO 3.1 MIB Tree Panel The left half of AMIGO's main window is the "MIB Tree Panel", which shows the MI
Allied Telesyn AT-VIEW PLUS AMIGO When you first run AMIGO, the Personal MIB tree is empty (root node only). To create your own tree, follow the step
Allied Telesyn AT-VIEW PLUS AMIGO Operations on the MIB tree are applied to the currently selected target device. To change the current target, click
Allied Telesyn AT-VIEW PLUS AMIGO 3.2 Detailed Information Panel The Detailed Information Panel is the area at the top right corner of AMIGO's
Allied Telesyn AT-VIEW PLUS AMIGO Copyright (c) 2003-2004 Allied Telesis K. K. All rights reserved. No part of t
Allied Telesyn AT-VIEW PLUS AMIGO 3.3 MIB Operation Panel The MIB Operation Panel is the area at the bottom right corner of AMIGO's main window
Allied Telesyn AT-VIEW PLUS AMIGO To change the value, check the variables to be changed before clicking the Set MIB Value button. AMIGO will send th
Allied Telesyn AT-VIEW PLUS AMIGO Note - SNMPv3: Depending on the WRITE VIEW access settings of the User Account Name used, there is a possibility th
Allied Telesyn AT-VIEW PLUS AMIGO 4 Menus This section describes AMIGO's menu bar items. These menu commands can also be accessed from the tool
Allied Telesyn AT-VIEW PLUS AMIGO 4.1 File From the File menu, you can open, change, or save AMIGO's configuration. Topics: • New File • Open
Allied Telesyn AT-VIEW PLUS AMIGO 4.1.6.1 Setting MIB-Files Tab In the Setting MIB-Files tab, you can specify which MIB files AMIGO uses to draw the
Allied Telesyn AT-VIEW PLUS AMIGO To change the properties of a specific target device, select the target device from the list, then click the Proper
Allied Telesyn AT-VIEW PLUS AMIGO SNMP version The version of SNMP that the device will use to send and receive device information. After choosing
Allied Telesyn AT-VIEW PLUS AMIGO 4.1.6.3.2 SNMP v3 Settings User Account Name This is the SNMPv3 User Account to be used for accessing the MIB of t
Allied Telesyn AT-VIEW PLUS AMIGO DES Use Data Encryption Standard Privacy Password If the Security Level is "Auth / Priv", you need to s
Allied Telesyn AT-VIEW PLUS AMIGO TABLE OF CONTENTS 1 Overview ...
Allied Telesyn AT-VIEW PLUS AMIGO Setting WWW browser tab 4.1.6.5 Window Layout Setting Tab In the "Window layout setting" tab, you can cu
Allied Telesyn AT-VIEW PLUS AMIGO Window display options for AMIGO 4.1.6.5.2 Toolbar Area You can select the appearance of the toolbar buttons. PN 6
Allied Telesyn AT-VIEW PLUS AMIGO Toolbar area submenu 4.1.6.5.3 MIB Tree Panel You can change the placement for the MIB Tree Panel, Detailed Inform
Allied Telesyn AT-VIEW PLUS AMIGO MIB tree panel submenu 4.1.6.5.4 Personal MIB Tree Area / General MIB Tree Area You can change the background colo
Allied Telesyn AT-VIEW PLUS AMIGO Background colour setting 4.1.6.5.5 MIB Node Description Area You can choose how to display the text in the Detail
Allied Telesyn AT-VIEW PLUS AMIGO Detailed information panel settings 4.1.6.5.6 MIB Operation Panel Submenu You can select the format of the MIB var
Allied Telesyn AT-VIEW PLUS AMIGO MIB variable name display type 4.1.7 Exit Quit AMIGO. 4 Menus PN 613-50662-00 Rev A Page 36 of 43
Allied Telesyn AT-VIEW PLUS AMIGO 4.2 Edit From the Edit menu, you can perform copy and paste operations on the MIB tree panel. These operations can
Allied Telesyn AT-VIEW PLUS AMIGO Search dialog box 4 Menus PN 613-50662-00 Rev A Page 38 of 43
Allied Telesyn AT-VIEW PLUS AMIGO 4.3 Mark From the Mark menu, you can mark particular MIB objects for later reference. After marking, you can acces
Allied Telesyn AT-VIEW PLUS AMIGO 4.2 Edit ...
Allied Telesyn AT-VIEW PLUS AMIGO 4.4 SNMP From the SNMP menu, you can perform the following SNMP operations. Topics: • Get Values • Get Values a
Allied Telesyn AT-VIEW PLUS AMIGO Get SNMP values of selected device Note - If you select a node containing many variables, for instance the whole m
Allied Telesyn AT-VIEW PLUS AMIGO Sets values to the variables. 4.4.4 Save Values Saves MIB values to a file. 4.4.5 Load Values From a File Loads MIB
Allied Telesyn AT-VIEW PLUS AMIGO PN 613-50662-00 Rev A Page 43 of 43 4.5 Help From the Help menu, you can view the online user's guide and
Allied Telesyn AT-VIEW PLUS AMIGO 1 Overview AMIGO (Advanced MIb Group Operator) is a MIB browser that comes with AT-View Plus. It is a tool for vi
Allied Telesyn AT-VIEW PLUS AMIGO 2 Starting AMIGO AMIGO can be started from AT-View Plus Device Manager or from the command line. In a Windows envi
Allied Telesyn AT-VIEW PLUS AMIGO 2.1 Starting From the Command Line The command line interface is the most basic way to start AMIGO. Topics: • Com
Allied Telesyn AT-VIEW PLUS AMIGO UserName User account name to be used for accessing the MIB. This is required when using SNMPv3. SecLevel Securit
Allied Telesyn AT-VIEW PLUS AMIGO Examples: Amigo -TargetHost 172.16.99.123 -SnmpVersion 1 Amigo -TargetHost 172.16.99.123 -SnmpVersion 2 2.1.4 Get
Comentarios a estos manuales