Allied-telesis AT-S62 Manual de usuario Pagina 232

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 420
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 231
Chapter 17: IGMP Snooping Commands
232
SET IP IGMP
Syntax
set ip igmp [snoopingstatus=enabled|disabled]
[hoststatus=singlehost|multihost] [timeout=value]
[numbermulticastgroups=value]
[routerport=port|all|none|auto]
Parameters
snoopingstatus Activates and deactivates IGMP snooping
on the switch. Possible settings are:
enabled Activates IGMP snooping.
disabled Deactivates IGMP snooping.
This is the default setting
hoststatus Specifies the IGMP host node topology.
Options are:
singlehost Activates the Single-Host/Port
setting, which is appropriate
when there is only one host
node connected to a port on
the switch. This is the default
setting.
multihost Activates the Multi-Host
setting, which is appropriate if
there is more than one host
node connected to a switch
port.
timeout Specifies the time period, in seconds, used
by the switch in determining inactive host
nodes. An inactive host node is a node that
has not sent an IGMP report during the
specified time interval. The range is 1 to
86,400 seconds (24 hours); the default is
260 seconds.
Vista de pagina 231
1 2 ... 227 228 229 230 231 232 233 234 235 236 237 ... 419 420

Comentarios a estos manuales

Sin comentarios