AT-S62 Management Software Menus Interface User’s Guide
Section II: Advanced Operations 351
6. To change the port’s priority, type 2 to select Power Priority and, when
prompted, type C for Critical, H for High, or L for Low. A port can
belong to only one priority level at a time. The default is Low. For an
explanation of this parameter, refer to “Port Prioritization” on page 346.
7. To change the maximum amount of power the port can supply to the
device, type 3 to select Power Limit and enter a new value in milliwatts.
The default value is 15,400 mW.
A change to a parameter value is immediately activated on the switch.
8. After making your changes, type R until you return to the Main Menu.
Then type S to select Save Configuration Changes.