AT-MCF2000 Media Converter Series Installation Guide
Section II: Installation 155
AT-MCF2000S Stacking Module
Problem 1: The Chassis ID number LEDs are off.
Solution: The AT-MCF2000S Module is not receiving power or has failed.
Try the following:
Verify that the STATUS LEDs on the power supply modules in the
chassis are steady green. If the LEDs are off or signalling a fault
condition, refer to “AT-MCF2000AC and AT-MCF2300AC Power
Supply Modules” on page 150 for troubleshooting ideas.
Verify that the AT-MCF2000S Module is fully seated in the
Management slot in the chassis.
Remove and reinstall the AT-MCF2000S Module.
Replace the module. If the replacement module works, the problem is
with the original module. If the replacement module does not work, the
problem is with the chassis.
Problem 2: A cable is connected to a Stack port but the port’s L/A LED is
off.
Solution: The Stack port is unable to establish a link with the Stack port in
the AT-MCF2000M Module or the AT-MCF2000S Module in the next
chassis. Try the following:
Check that the cable is firmly connected to the Stack ports on both
chassis.
Verify that the next chassis in the stack is powered on and is operating
properly.
Verify that the cable does not exceed 100 meters (328 feet).
Check that the cable is a standard straight-through or crossover TIA/
EIA 568-B-compliant Enhanced Category 5 (Cat 5e) shielded or
unshielded cable with 100 ohm impedance.