Start-up Sequence
Software Reference for x310 Series Switches
3.6 AlliedWare Plus
TM
Operating System - Version 5.4.4C C613-50046-01 REV A
You can select a one-off boot from Flash, USB storage device, network server (TFTP), or
ymodem. The selected option will be used for the next restart (only) of the switch. If you
select to boot from the network, the bootloader prompts the user for the required
network address details.
.
When the switch is booted up using the ‘one-off’ selected source for the software release,
it provides the option to copy the release just used to Flash for further/ permanent use:
Note
These settings are specific to the Bootloader.
They are not related in any way to what may be configured by the main
software release.
Enter IP version [4|6]......... [4]:
Enter IP address for eth0 ..... [0.0.0.0]: 172.28.8.210
Enter subnet mask ............. [0.0.0.0]: 255.255.0.0
Enter gateway IP .............. [0.0.0.0]: 172.28.0.1
Enter TFTP server IP .......... [0.0.0.0]: 172.30.1.242
Enter filename ................ []: x310-5.4.4C.rel
Loading tftp://172.30.1.242/x310-5.4.4C.rel...
login: manager
Password: ******
The system has been booted using the one off boot/recovery
mechanism.
Bootup has successfully completed.