Allied-telesis AT-S83 Manual de usuario Pagina 230

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 382
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 229
Chapter 11: 802.1x Access Control Commands
230
RADIUS-SERVER TIMEOUT
Syntax
radius-server timeout <1-1000>
no radius-server timeout
Parameters
<1-1000> Specifies the time in seconds. Choose a value between 1
and 1,0000.
Description
Use the RADIUS-SERVER TIMEOUT command to specify the length of
time before communication between the switch and the RADIUS host
times out. To set this command to its default value, use the no form of this
command. The default time is 5 seconds.
Command Mode
Configure mode
Example
The following commands set the timeout value to 120 seconds:
switch# configure terminal
switch(config)# radius-server timeout 120
Related Commands
none
Vista de pagina 229
1 2 ... 225 226 227 228 229 230 231 232 233 234 235 ... 381 382

Comentarios a estos manuales

Sin comentarios