Allied-telesis AT-S102 Manual de usuario Pagina 64

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 374
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 63
Chapter 3: OAM-based Features
64
Refer to Table 8 for the required version levels of the management
software.
First RPS Failure The AT-CM Line Cards send this signal if the AT-CV1203 Chassis has
both a primary power supply and a redundant power supply, and just one
of the power supplies loses power. The signal indicates that the remote
chassis is continuing to operate after having lost power on one of its power
modules.
The following subsections explain how this feature works on the AT-CM2
and AT-CM3 Line Cards.
Table 7. Versions of the AT-CM2 Line Cards that Support Dying Gasp
Media Converter Line Card Hardware Version
AT-CM201 Version 2
AT-CM202 Version 2
AT-CM202/1 Version 2
AT-CM202/2 Version 2
AT-CM212A/1 Version 2
AT-CM212B/1 Version 2
AT-CM70S Version 2
AT-CM2K0S Version 3
Table 8. Versions of the Management Software that Support Dying Gasp
Management and Media
Converter Line Cards
Management Software Versions
AT-CV5M01 Management Card Version 2.0.2 or later of the
AT-S70 Management Software.
AT-CV5M02 Management Card Version 3.0.0 or later of the
AT-S99 Management Software
AT-CM2 Line Cards Version 2.0.2 or later of the
AT-S73 Line Card Management
Software.
AT-CM3 Line Cards Version 3.0.0 or later of the
AT-S102 Line Card Management
Software.
Vista de pagina 63