Chapter 5: Configuring the AT-CV5M02 Management Card
128
SFP Tx Bias High|Low
Alarm (local) in linecard n
Report The laser bias of an SFP module either
exceeded the operating range (High) or
dropped below the range (Low).
Clear The laser bias of an SFP module returned
to the operating range.
SFP Tx Power High|Low
Alarm (local) in linecard n
Report The laser output of an SFP module either
exceeded the operating range (High) or
dropped below the range (Low).
Clear The laser output of an SFP module
returned to the operating range.
SFP Rx Power High|Low
Alarm (local) in linecard n
Report The laser input of an SFP module either
exceeded the operating range (High) or
dropped below the range (Low).
Clear The laser input of an SFP module
returned to the operating range.
Remote Messages
Remote SFP Temp
High|Low Alarm in linecard
n
Report The operating temperature of a remote
SFP module either exceeded the
operating range (High) or dropped below
the range (Low).
Clear The operating temperature of a remote
SFP module returned to the operating
range.
Remote SFP Vcc High|Low
Alarm in linecard n
Report The input voltage of a remote SFP
module either exceeded the operating
range (High) or dropped below the range
(Low).
Clear The input voltage of a remote SFP
module returned to the operating range.
Remote SFP Tx Bias
High|Low Alarm in linecard
n
Report The laser bias of a remote SFP module
either exceeded the operating range
(High) or dropped below the range (Low).
Clear The laser bias of a remote SFP module
returned to the operating range.
Table 14. SFP Module Event Messages
Message Classification Definition