Converteon Management Software User’s Guide
255
5. From the OAM Configuration Menu, select OAM Configuration to
display the OAM Configuration submenu, shown in Figure 106.
Figure 106. OAM Configuration Submenu
The parameters in the OAM Configuration submenu are defined in
Table 31. The line card immediately implements your changes to the
parameters.
OAM Configuration
Module 4, Port A
Admin State Enabled
Mode Passive
Maximum OAMPDU Size 1518
Unidirectional Support Yes
Loopback Support Yes
Link Event Support No
Variable Retrieval Support Yes
Return to OAM Configurations ...
Table 31. OAM Client Parameters
Parameter Description
Admin State This parameter controls the state of the OAM client on
the line card and has the following possible values:
Enabled – This enables the OAM client. The line card
can participate in the OAM Discovery process and
perform other OAM functions. This is the appropriate
setting for the OAM-based features on the AT-CM
Line Cards. This is the default setting.
Disabled – This disables the OAM client. The line
card cannot participate in the OAM Discovery
process because it will not generate or respond to
OAMPDUs.