AT-S100 Management Software User’s Guide
Section I: Command Modes 117
CLOCK SUMMER-TIME RECURRING
Syntax
clock summer-time ZONENAME recurring START-WEEK START-
DAY START-MONTH START-TIME END-WEEK END-DAY END-MONTH
END-TIME <1-180>
no clock summer-time
Parameters
ZONENAME Describes the summertime zone, up to 6 characters
long.
recurring Specifies that this summertime setting applies every
year from now on.
START-WEEK Indicates the week of the month when summertime
starts in the range of 1 to 5. The value of 5 indicates
the last week that has specified day in it for the
specified month. For example, to start summertime
on the last Sunday of the month, enter 5 for START-
WEEK and “sun” for START-DAY.
START-DAY Indicates the day of the week when summertime
starts. Use the first three letters of each day of the
week. Valid values are “mon,” “tue,” “wed,” “thu,” “fri,”
“sat,” and “sun.”
START-MONTH Specifies the month that summer time starts. Use the
first three letters of each month to indicate the name
of a month. Valid values are “jan, “feb,” “mar,” “apr,”
“may,” “jun,” “apr,” “may,” “jun,” “jul,” “aug,” “sep,”
“oct,” “nov,” and “dec.”
START-TIME Indicates the time of day that summer time starts in
24-hour format: HH:MM where H represents hours
and M represents minutes.
END-WEEK Indicates the week of the month when summer time
ends in the range of 1 through 5. The value of 5
indicates the last week of the month.
END-DAY Specifies the day of the week when summer time
ends. Use the first three letters of each day of the
week. Valid values are “mon,” “tue,” “wed,” “thu,” “fri,”
“sat,” and “sun.”