7.1 RMON-specific Buttons
The RMON window is slightly different from the MIB variable windows. The RMON window
has several tabs and each tab has the following tool buttons in addition to the buttons in the MIB
variable windows.
Absolute Value
Displays collected data as they are.
Per Sample
Displays the difference between the last two sampled values. The value is rounded.
Per Second
Displays the difference between the last two sampled values per second. This is (Current
value - Previous value) / Polling Interval. The value is rounded.
Start Polling
Restarts polling.
Stop Polling
Pauses polling. This may be useful for examining current data carefully.
Refresh
Forces immediate polling and displays the latest sampled value regardless of the regular
polling timer.