AlliedView™-EMS 4.0.2 Device Management Guide Page 432 of 441
AT-PB1000 Series Media Converter Modules
PB1001/1 PB1001/3 PB1005G
LED State Description
LT Green Link Test is enabled
SML Green Smart Missing Link is enabled
ML Green Missing Link is enabled
Note - Smart Missing Link is only supported on the AT-PB1005G module. However, the
current firmware version allows the Link Test parameter of the AT-PB1001/1 and AT-
PB1001/3 modules to be set to 'smart-missing-link'.
Note - The Port A Mode and the Port B Mode parameters return 'not supported' for these
modules.
Note - A GBIC image is always visible on the GBIC slot of the PB1005G module image even
if there is no GBIC physically present in the slot.