AT-S70 Management Software User’s Guide
193
The following prompt is displayed:
Enter Security Model [1-v1, 2-v2c, 3-v3]:
7. Enter the Security Model configured for this User Name. You cannot
change the value of the Security Model parameter.
Select one of the following SNMP protocols:
1-v1
Select this value if this User Name is configured with the SNMPv1
protocol.
2-v2c
Select this value if this User Name is configured with the SNMPv2c
protocol.
3-v3
Select this value if this User Name is configured with the SNMPv3
protocol.
The following prompt is displayed:
Enter Storage Type [V-Volatile, N-NonVolatile]:
8. Select one of the following storage types for this table entry:
V-Volatile
Select this storage type if you do not want the ability to save an entry in
the SNMPv3 Group Table to the configuration file.
N-NonVolatile
Select this storage type if you want the ability to save an entry in the
SNMPv3 Group Table to the configuration file. Allied Telesis
recommends this storage type.
9. From the Main Menu, select System Configuration.
The System Configuration Menu is displayed, as shown in Figure 10
on page 46.
10. From the System Configuration Menu, select Save Configuration
File.
Displaying the
SNMPv3 Group
Table Menu
This section describes how to display the Display SNMPv3 Group Table
menu. For more information about the parameters in the SNMPv3 Group
Table menu, see “Creating an SNMPv3 Group Table Entry” on page 186.
To display the Display SNMPv3 Group Table menu, perform the following
procedure.
1. From the Main Menu, select System Configuration.