Allied-telesis AT-S62 Manual de usuario Pagina 197

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 372
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 196
AT-S62 Management Software Web Browser Interface User’s Guide
Section II: Advanced Operations 197
The Maximum Available Power field displays the maximum amount of
PoE available from the switch for the powered devices connected to its
ports. This value is 400W for the AT-8524POE switch. This value
cannot be changed.
4. In the Power Threshold field, enter the new threshold value as a
percentage of the total available PoE power on the switch. As an
example, to configure the switch to enter an event in the event log and
send an SNMP trap when power consumption exceeds 300 W, you
would enter 75, for 75%.
5. Click Apply.
The new threshold is immediately activated on the switch.
6. To permanently save the change, select the Save Config menu
selection.
Vista de pagina 196
1 2 ... 192 193 194 195 196 197 198 199 200 201 202 ... 371 372

Comentarios a estos manuales

Sin comentarios