Allied-telesis AT-8202 Manual de usuario Pagina 51

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 80
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 50
AT-8202 ATM Uplink User’s Guide
2-23
ATM/SHOW/CIP Example
This command displays a summary of all existing CIP entities. A
sample display of
ATM/SHOW/CIP is shown below, and parameters
are described in Table 2-9.
/ATM/SHOW >CIP
CIP CIP IP Network PVC/ VCI Server
ID Description Address SVC Value ATM Address
=== =========== ========== ==== ===== ==========================================
1 CIP Test 1 137.168.132.9 SVC - 0x47000580ffe1000000f215149500204815149500
2 CIP Test 2 200.2.2.2 PVC 400
Table 2-9 ATM/SHOW/CIP Parameters
Parameter Description
CIP ID A unique identifier for each entry
Range: 1-31
CIP Description A user-defined textual description for this CIP entity
IP Network Address IP address associated with this CIP
PVC/SVC Whether this CIP is configured for permanent virtual circuit or switched
virtual circuit operation
VCI Value If PVC, the VCI value of the connection identifier
Server ATM Address If SVC, the ATM Address of the ARP server