AT-8202 ATM Uplink User’s Guide
1-9
3. Bind the port service to the LEC by entering:
PORTSERV/CONFIG/CREATE 34
Note
The value, 34, is the ATM uplink’s port number designation. This port
number is fixed; you cannot change it.
Table 1-3 LEC Configuration Parameters
Parameter Description
LEC Number The LEC index for this LEC
Range: 0-31
LEC Description (Optional) Optional text description of up to 31 characters
ELAN Name The name of the ELAN of which this LEC is a member (AUTO mode only)
Use LEC Config Server ATM Configuration mode
Options: Yes or No
LEC Config Server ATM
Address
If the configuration mode is Yes, the ATM address of the LECS. If the
configuration mode is No, the ATM address of the LAN emulation server
(LES)
Control Time-out Join request timeout
Range: 10 – 300 seconds
Max. Unknown Frame Count Maximum unknown frame count
Range: 1 – 10.
Default: 1
Max. Unknown Frame Time Maximum unknown frame time
Range: 1 – 60 seconds
Default: 1 second
VCC Time-out VCC entry aging timer.
Default: 1200 second
Max. Retry Count Maximum retries for LE ARP entry
Range: 0 – 2
Ageing Time LE ARP entry aging
Range: 10 – 300 seconds
Expected LE-ARP Resp Time Expected LE ARP response time
Range: 1 – 30 seconds
Flush Time-out Flush request timeout
Range: 1 – 4 seconds