Chapter 10: User Diagnostics
114
Performing Diagnostics
At the MS-DOS prompt, type uediag followed by the command options.
The uediag command options are shown in Table 10. For example, to run
all of the diagnostic tests except Group B tests on adapter #1, enter:
C:\>uediag -c 1 -t b
You must include uediag at the beginning of the command string
each time you type a command.
Not all commands are supported on all adapters.
Table 10. uediag Command Options
Command Option Description
uediag Performs all tests on all the ANC10S
networks adapters in your system.
uediag -c <devnum> Specifies the adapter (devnum) to test.
Use all in place of a specific device
number to test all adapters.
uediag -cof Allows tests to continue after detecting
a failure.
uediag -F Forces an upgrade of the image
without checking the version.
uediag -fbc <bc_image> Specifies the bin file to update the
bootcode.
uediag -fipmi
<ipmi_image>
Specifies the bin file to update IPMI
firmware.
uediag -fmba
<mba_image>
Specifies the bin file to update the
MBA.
uediag -fncsi
<ncsi_image>
Specifies the bin file to update the
NCSI firmware.
uediag -fnvm
<raw_image>
Programs the raw image into NVM.