Allied-telesis AT-S97 Manual de usuario Pagina 86

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 218
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 85
Chapter 5: Port and Module Commands
86
SYSTEM SHOW CHASSIS
Syntax
system show chassis id=
chassis
Parameters
id Identifies the ID number of a chassis. You can specify only
one chassis at a time. In version 1.3.0, the chassis ID
number is 0 or 31. To view a unit’s ID number, use the
SYSTEM SHOW CLUSTER command. For instructions,
refer to “SYSTEM SHOW CLUSTER” on page 88.
Privilege Levels
Administrator, read-write and read-only.
Description
This command displays the model names and slot assignments of the
management and media converter modules in a chassis, as well as the
chassis’ module name and MAC address. This command does not display
power supply or fan modules.
This command can display just one chassis at a time. To view all of the
chassis of a stack with one command, use the SYSTEM SHOW
CLUSTER command, as explained in “SYSTEM SHOW CLUSTER” on
page 88.
An example of the information is shown in Figure 8.
Figure 8. SYSTEM SHOW CHASSIS Command
Chassis Chassis Chassis MAC Master
ID Name Type Address Chassis
------------------------------------------------------------------
0 AT-MCF2000 11:22:33:44:55:55 Yes
Slot ID Module Name Module Type Software Version
------------------------------------------------------------
M AT-MCF2000M v1.3.0
1 AT-MCF2012LC v1.3.0
2 AT-MCF2012LC v1.3.0