Allied-telesis AT-S41 Manual de usuario Pagina 76

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 236
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 75
AT-S41 User’s Guide
76
5. Type M to select Set Monitored Port.
The following prompt is displayed:
Set monitored port->Enter port number>
6. Enter the number of the port whose traffic is to be monitored. The
default monitored port is Port 1. You can specify only one port to be
monitored. Press Enter.
The port number you have just entered is displayed under the
Monitored Port heading on the Port Monitoring Configuration
Menu.
7. Type E to select Enable/Disable Port Monitoring.
The following prompt is displayed.
Enable or Disable monitoring (E/D)>
8. Type E to enable port monitoring. The status will change to Enabled
on the Port Monitoring Configuration Menu.
Port monitoring is now functional.