Chapter 5: Port and Module Commands
114
The fields are defined here:
Examples
This command displays information about the AT-MCF2000M
Management Module in a chassis with an ID number of 0:
system show module id=0/m
Table 13. SYSTEM SHOW MODULE Command
Parameter Description
Module Name Displays the name of the module. Refer to “SYSTEM SET
MODULE” on page 89 for instructions on how to assign a
name to a module.
Module Type Displays the model name.
Power OK Displays the status of the input power of a power supply
module or a fan module A status of Yes signifies the input
power is within the module’s operating range. A status of No
signals that the input power is less or greater than the
permitted range.
Voltages Displays the operating output voltages for the AT-MCF2000AC
Power Supply Module and input voltages for all other modules.
Temperature Displays the current temperature of a module. On the
AT-MCF2000AC Power Supply Module and the
AT-MCF2KFAN Fan Module the temperature is measured at
the point where the outside air enters the chassis from the
cooling vents. The temperature for all the other modules is
measured on the circuit boards.
Temperature Threshold Displays the temperature threshold of a module. The
management module logs an event in the event log if the
threshold is exceeded, to warn of possible excessive
temperature in the wiring closet or chassis. Refer to “SYSTEM
SET MODULE” on page 89 for instructions on setting a
module’s temperature threshold.
Management Port Displays the status of the link of the 10/100/1000Base-T
Management port on the AT-MCF2000M Management Module
and, if the port has a link to a network device, the current
settings. Refer to “SYSTEM SET PORT” on page 92 for
instructions on setting the parameters of the port.
Stacking Port Displays the status of the Stack port connection on the
AT-MCF2000M Management Module. A status of Up indicates
the port has established a link with a Stack port in another
chassis.