
AT-MCM02 Management Module Installation Guide
5
Installing the Management Module
To install the management module in your multichannel media converter,
perform the following procedure:
Warning
Installing the AT-MCM02 Management Module while the media
converter is powered ON could result in damage to the module.
1. Power OFF the media converter by performing one of the following:
❑ For an AC model, unplug the power cord from the power outlet and
then unplug the power cord from the media converter.
❑ For a DC model, follow the steps below:
Warning
When installing this equipment, alway ensure that the frame ground
connection is installed first and disconnected last. $ 15
a. Remove the positive and negative feed wires from the terminal block
by loosening the screws to the wire connections with a flathead
screwdriver.
b. Remove the frame ground wire from the terminal block by loosening
the screw to the wire connection with a flathead screwdriver.
2. Using a Phillips-head screwdriver, remove the blank faceplate from the
management module expansion slot, located on the back panel of the
media converter. See Figure 1.
Figure 1 Removing the Blank Faceplate
3. Remove the management module from the package and store the
packaging in a safe place.
Management
Port
>
Power Supply
<
Main
<<
Back-Up
AC LINE
100-240 VAC
50-60 Hz
1.5A MAX
50 W
Comentarios a estos manuales