Converteon Media Converter Line Cards Reference Guide
103
Back-to-Back – Converteon™ Module Configured for Link Test
Figure 50 on page 102 shows a back-to-back configuration for two
Converteon™ modules (Module A and Module B) that has been
configured for the Link Test mode. Refer to “Link Test” on page 44 for
configuring the module of the Link Test mode. Module A is connected to
an AT-8524M (Switch 1) with a copper cable and to Module B with a dual
fiber cable. Module B is connected to a AT-8524M (Switch 2) with a copper
cable.
Table 30 shows the Link LED status for each of the ports involved when
the cables are connected and disconnected from Module A's ports.
Table 30. Back-to-Back – Converteon™ Module in Link Test Mode
Network
Device
Port
Link
Converteon™ Module Cable Status
All Cables
Connected
Copper Cable
Switch 1 to
Module A -
Disconnected
Module A
Transmit/
Receive
Fiber Cable
Disconnected
Port
LINK
Status
Switch 1 Copper
LK LED
ON OFF ON
Converteon™
Module A
Copper
LK LED
ON OFF ON
Fiber
LK LED
ON ON OFF
Converteon™
Module B
Fiber
LK LED
ON ON OFF
Copper
LK LED
ON ON ON
Switch 2 Copper
LK LED
ON ON ON