Converteon Media Converter Line Cards Reference Guide
101
Stand Alone – Converteon™ Module Configured for Smart
MissingLink Test
Figure 49 on page 98 shows a stand-alone configuration for a
Converteon™ module (Module A) that has been configured for the Smart
MissingLink Test mode. Refer to “Smart MissingLink” on page 45 for
configuring the module of the Smart MissingLink Test mode. Module A is
connected to an AT-8524M (Switch 1) with a copper cable and to an
AT-8516F/SC (Switch 2) with a dual fiber cable.
Table 29 shows the Link (LK) LED status for each of the ports involved
when the cables are connected and disconnected from Module A's ports.
Table 29. Stand-Alone – Converteon™ Module in Smart MissingLink Test Mode
Network
Device
Port
Link
Converteon™ Module Cable Status
All Cables
Connected
Copper Cable
Switch 1 to
Module A -
Disconnected
Module A
Transmit/
Receive
Fiber Cable
Disconnected
Port
LINK
Status
Switch 1 Copper
LK LED
ON OFF Blinking
Converteon™
Module A
Copper
LK LED
ON OFF Blinking
Fiber
LK LED
ON Blinking OFF
Switch 2 Fiber
LK LED
ON Blinking OFF
Vista de pagina 100