Autumn 2011 | 19
Power over Ethernet Switches
SUBCATEGORY FEATURE AT-FS708/POE AT-FS750/24POE AT-GS950/8POE AT-8000/8POE AT-8000S/24POE AT-8000S/48POE AT-8624POE-V2 AT-8000GS/24POE AT-x600-24Ts-POE AT-x600-24Ts-POE+ x610 SERIES 8100L and 8100S SERIES
FORM FACTOR
» Wall mountable
» Desktop
» Rack mountable
» Wall mountable
» Desktop
» Rack mountable
» Wall mountable
» Desktop
» Rack mountable
» Wall mountable
» Desktop
» Rack mountable
» Wall mountable
» Desktop
» Rack mountable
» Wall mountable
» Desktop
» Rack mountable
» Desktop
» Rack mountable
» Wall mountable
» Desktop
» Rack mountable
» Desktop
» Rack mountable
» Stackable
» Desktop
» Rack mountable
» Stackable
See page 12 for the
new x610 Series
Layer 3+ Gigabit
PoE+ Switches
See page 10 for the
8100L and 8100S
Series Fast Ethernet
PoE+ Switches
SWITCH FUNCTIONALITY
Unmanaged WebSmart WebSmart Layer 2 Layer 2
Layer 2 Layer 3 Layer 2 Layer 3 Layer 3
PORTS AND
MEDIA SUPPORT
10/100TX 8 24 8 24
48 24
10/100/1000T 2 8 1 (combo) 2 2 2 24 24 24
SFP
1
1000Mbps
2 (combo)
100 or 1000Mbps
2 (combo)
100 or 1000Mbps
1
1000Mbps
2 (combo)
100 or 1000Mbps
2 (combo)
100 or 1000Mbps
2 (combo)
1000Mbps
4 (combo)
100 or 1000Mbps
4 (combo)
1000Mbps
4 (combo)
1000Mbps
Modular uplinks 2
MODULAR UPLINKS
1 x 100FX AT-A45
POWER SUPPLY
PSU type Fixed internal Fixed internal Fixed internal Fixed internal Fixed internal Fixed internal Fixed internal Fixed internal Fixed internal Fixed internal
Redundant PSU option
■ ■ ■
Redundant PSU chassis (inc 1 PSU) AT-RPS3104 AT-RPS3104 AT-RPS3104
Additional redundant PSU AT-PWR3101 AT-PWR3101 AT-PWR3101
POWER OVER ETHERNET
IEEE 802.3af Class 3
■ ■ ■ ■ ■
■ ■ ■ ■ ■
IEEE 802.3at Class 4
■
PoE-enabled ports 8 12 4 8 24 48 24 24 24 24
Max number of full power ports 4 6 4 6 12 24 24 9 24 12
Mode A A B B B B A A A A
PoE power 65W 100W 60W 95W 180W 375W 400W 140W 370W 370W
SCALABILITY
MAC address table size 8K 8K 8K 8K 8K
8K 8K 8K 16K 16K
Stacking ■ (6) ■ (6) ■ (6) ■ AT-StackXG (4) ■ AT-StackXG (4)
ENVIRONMENTAL
Cooling Fanless Fan Fanless Fan Fan
Fan Fan Fan Fan Fan
ECO-switch
■ ■
MANAGEMENT
Web
■ ■ ■
■ ■ ■ ■ ■
CLI
■ ■
■ ■ ■ ■ ■
Telnet
■ ■
■ ■ ■ ■ ■
SNMP
■ ■ ■ ■
■ ■ ■ ■ ■
NETWORK RESILIENCE
Spanning Tree
■ ■ ■ ■
■ ■ ■ ■ ■
Link aggregation (LACP)
■ ■ ■
■ ■ ■ ■ ■
QoS
IEEE 802.1p priority queues 4 4 4 4 4 4 8 8
SECURITY
IEEE 802.1Q VLANs 256 256 256 256 256 256 4096 4096 4096
RADIUS
■ ■ ■
■ ■ ■ ■ ■
TACACS+
■
■ ■ ■
TACACS+ TACACS+
SSH/SSL
■ ■ ■ ■ ■
IEEE 802.1x
■ ■ ■
■ ■ ■ ■ ■
DoS protection
■ ■ ■
ROUTING
IPv4/IPv6 IPv4 only
■ ■
DIMENSIONS
(W x D x H)
26.5 x 16.2 x 4.3 cm
10.4 x 6.4 x 1.7 in
44 x 25.7 x 4.3 cm
17.3 x 10.1 x 1.7 in
32 x 23 x 4.3 cm
13 x 9.1 x 1.7 in
33 x 22.8 x 4.3 cm
13 x 8 x 1.7 in
44 x 25.7 x 4.3 cm
17.3 x 10.1 x 1.7 in
44 x 34.7 x 4.3 cm
17.3 x 13.7 x 1.7 in
43.8 x 40.6 x 4.4 cm
17.24 x 15.98 x 1.73 in
44 x 25.7 x 4.3 cm
17.3 x 10.1 x 1.7 in
44 x 40.8 x 4.4 cm
17.3 x 16.1 x 1.73 in
44 x 40.8 x 4.4 cm
17.3 x 16.1 x 1.73 in
Weight 1.9 kg / 4.2 lb 4.133 kg / 9.11 lb 2.54 kg / 5.6 lb 2.2 kg / 4.9 lb 3.7 kg / 8.15 lb 5.6 kg / 12.34 lb 6 kg / 13.22 lb 3.5 kg / 7.71 lb
6.90 kg / 15.2 lb
(unpackaged)
6.90 kg / 15.2 lb
(unpackaged)
NEW
Power Budget
Users should ensure that the maximum
power drawn by all the PDs does not
exceed the maximum power that can be
delivered by the PSE. If this occurs, the
switch will use a predetermined algorithm
to determine which ports will receive
power. See user manuals for details on
each switch.
Cable Types
PoE is designed to run over existing
standard Ethernet cables. However, for
Fast Ethernet, there are two modes of
operation:
» Mode A – Injects power onto the data
wires
» Mode B – Uses “spare pairs” to transmit
the power
Gigabit copper connections use all four
pairs to connect.
Power Injectors
Allied Telesis also offers a power injector
and power splitter which can be used
to inject or extract power over a single
Unshielded Twisted Pair (UTP) connection:
» AT-6101G power injector
» AT-6102G power splitter
Comentarios a estos manuales