Appendix A: Technical Specifications
120
Fiber Optic Specifications of the AT-StackOP/0.3 and AT-StackOP/9.0
Transceivers
Table 22 lists the fiber optic port specifications for the AT-StackOP/0.3
transceiver.
Table 23 lists the fiber optic port specifications for the AT-StackOP/9.0
transceiver.
Table 22. Fiber Optic Port Specifications for the AT-StackOP/0.3 Module
General
Maximum Distances 33 m with 62.5/125 µm (core/
cladding) multimode fiber optic
cable
300 m with 50/125 µm (core/
cladding) multimode fiber optic
cable
Fiber Optic Cable 50/125 µm or 62.5/125 µm (core/
cladding) multimode fiber optic
cable
Transmitter
Wavelength 850 nm
Output Optical Power -7.3 dBm min.
Receiver
Wavelength 850 nm
Maximum Sensitivity -9.9 dBm
Maximum Input Power -1 dBm
Table 23. Fiber Optic Port Specifications for the AT-StackOP/9.0
Transceiver
General
Maximum Distances 9 km
Fiber Optic Cable 9/125 µm (core/cladding) single-
mode fiber optic cable