Allied Telesyn AT-VIEW PLUS
DEVICE MANAGEMENT
Device Manager LEDs for AT-8748XL
LED State Description
PWR
Green
Red
The switch is receiving power from the main power supply.
Main power supply is either off or has failed.
RPS
Green
Red
Gray
The switch is receiving power from the redundant power
supply.
RPS has failed.
RPS is not installed or RPS monitoring is disabled.
DUPLEX
Green
Orange
The port is operating at full duplex.
The port is operating at half duplex.
Device Manager LEDs for AT-8748XL-DC
LED State Description
PWR Green The switch is receiving power.
DUPLEX
Green
Orange
The port is operating at full duplex.
The port is operating at half duplex.
Note - AT-8748XL and AT-8748XL-DC share the same device image.
Note - Please refer to Uplink Modules for the operations and behavior of the uplink modules
installed in this device.
Note - To turn RPS monitoring on or off on the switch, from the switch command line interface
enter the command SET SYSTEM RPSMONITOR={ON|OFF}. To see whether RPS monitoring
is on, use the command SHOW SYSTEM. To turn on RPS monitoring using SNMP, set the
fanAndPsRpsMonitoringStatus variable to on.
Note - The current firmware version does not allow AT-View Plus Device Manager to support
the Reset button.
Note - The current firmware version does not allow AT-View Plus Device Manager to support
the RPS LED on the AT-8748XL-DC model.
Agent Menu
From the Agent menu, you can view and edit the system information for the switch, or log into
the CLI using Telnet.