Chapter 4: SNMPv1 and SNMPv2 Community Strings
Section I: Basic Operations 48
Enabling or Disabling SNMP Management
To enable or disable SNMP management on the switch, perform the
following procedure:
1. From the Home page, select Configuration.
2. Select the Mgmt. Protocols menu option.
3. Select the SNMP tab.
The SNMP tab is shown in Figure 11.
Figure 11 SNMP Tab (Configuration)
4. Click Enable SNMP Access to enable or disable SNMP management.
A check in the box indicates that the feature is enabled, meaning that
the switch can be managed from an SNMP management workstation.
No check indicates that the feature is disabled. The default is disabled.
5. If you want the switch to send authentication failure traps, click
Enable Authentication Failure Traps. A check in the box indicates
that the switch will send the trap.
6. Click Apply.