Allied-telesis AT-IFS802SP Manual de usuario

Busca en linea o descarga Manual de usuario para Hardware De La Computadora Allied-telesis AT-IFS802SP. Allied Telesis AT-IFS802SP User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 101
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
613-001690 Rev.A
AT-IFS802SP
8x10/100TX POE Layer 2 Managed Industrial Switch
AT-IFS802SP Installation and
User’s Guide
Vista de pagina 0
1 2 3 4 5 6 ... 100 101

Indice de contenidos

Pagina 1 - User’s Guide

613-001690 Rev.A AT-IFS802SP 8x10/100TX POE Layer 2 Managed Industrial SwitchAT-IFS802SP Installation andUser’s Guide

Pagina 2

6 AT-IFS802SP-80 User ManualChapter 1 IntroductionThe 8 10/100TX + 2 10/100/1000T/SFP Combo with X-Ring L2 Managed Industrial Switch is a cost-effect

Pagina 3 - Industry Canada

96 AT-IFS802SP-80 User ManualSNTP Commands SetNetstar Commands Level Description Examplesntp enable G Enable SNTP function switch(cong)#sntpenablesn

Pagina 4

97AT-IFS802SP-80 User ManualX-ring Commands SetNetstar Commands Level Description Examplering enable G Enable X-ring switch(cong)#ringenablering mas

Pagina 5

7AT-IFS802SP-80 User ManualNetwork Cable10Base-T: 2-pair UTP/STP Cat. 3, 4, 5/ 5E cableEIA/TIA-568 100-ohm (100m)100Base-TX: 2-pair UTP/STP Cat. 5/ 5E

Pagina 6

8 AT-IFS802SP-80 User Manual1.2 Software FeaturesManagement SNMP v1 v2c, v3/ Web/Telnet/CLI/NS-ViewSNMP MIBRFC 1215 Trap, RFC1213 MIBII, RFC 1157 SNM

Pagina 7

9AT-IFS802SP-80 User ManualRelay AlarmProvides one relay output for port breakdown, power fail Alarm Relay current carry ability: 1A @ DC24VSNMP TrapU

Pagina 8

10 AT-IFS802SP-80 User ManualChapter 2 Hardware DescriptionIn this paragraph, it will describe the Industrial switch’s hardware spec, port, cabling i

Pagina 9

11AT-IFS802SP-80 User Manual2.3 Top ViewThe top panel of the 8 10/100TX + 2 10/100/1000T/SFP Combo with X-Ring L2 Managed Industrial Switch has one t

Pagina 10 - Chapter 1 Introduction

12 AT-IFS802SP-80 User Manual2.4 LED IndicatorsThe diagnostic LEDs that provide real-time information of system and optional status are located on th

Pagina 11

13AT-IFS802SP-80 User ManualChapter 3 Hardware InstallationIn this paragraph, we will describe how to install the 8 10/100TX + 2 10/100/1000T/SFP

Pagina 12 - 1.2 Software Features

14 AT-IFS802SP-80 User Manual3.2 DIN-Rail MountingThe DIN-Rail is screwed on the industrial switch when out of factory. If the DIN-Rail is not screwe

Pagina 13 - 1.3 Package Contents

15AT-IFS802SP-80 User Manual3.3 Wall Mount Plate MountingFollow the steps below to mount the industrial switch with wall mount plate.Remove the DIN-R

Pagina 14 - 2.2 Front Panel

Copyright © 2012 Allied Telesis, Inc.All rights reserved. No part of this publication may be reproduced without prior written permission from Allied T

Pagina 15 - 2.3 Top View

16 AT-IFS802SP-80 User Manual3.4 Wiring the Power InputsPlease follow the steps below to insert the power wire.Insert AC or DC power wires into the c

Pagina 16 - 2.4 LED Indicators

17AT-IFS802SP-80 User Manual3.5 Wiring the Fault Alarm ContactThe fault alarm contacts are in the middle of the terminal block connector as the pictu

Pagina 17 - 3.1 Installation Steps

18 AT-IFS802SP-80 User Manual3.6 CablingUse four twisted-pair, Category 5e or above cabling for RJ-45 port connection. The cable between •the switc

Pagina 18 - 3.2 DIN-Rail Mounting

19AT-IFS802SP-80 User ManualTo remove the LC connector from the transceiver, please follow the steps shown below:First, press the upper side of the LC

Pagina 19

20 AT-IFS802SP-80 User ManualChapter 4 Network ApplicationThis chapter provides some sample applications to help user to have more actual idea of ind

Pagina 20 - 3.4 Wiring the Power Inputs

21AT-IFS802SP-80 User Manual4.2 Coupling Ring ApplicationIn the network, it may have more than one X-Ring group. By using the coupling ring function,

Pagina 21

22 AT-IFS802SP-80 User Manual4.3 Dual Homing ApplicationDual Homing function is to prevent the connection lose from between X-Ring group and upper le

Pagina 22 - 3.6 Cabling

23AT-IFS802SP-80 User ManualChapter 5 Console Management5.1 Connecting to the Console PortThe supplied cable which one end is RS-232 connector and t

Pagina 23

24 AT-IFS802SP-80 User Manual5.3 Login in the Console Interface When the connection between Switch and PC is ready, turn on the PC and run a terminal

Pagina 24 - 4.1 X-Ring Application

25AT-IFS802SP-80 User Manual5.5 Commands LevelModes Access Method Prompt Exit Method About This Mode1User EXECBegin a session with your switch.switch

Pagina 25

3Electrical Safety and Emissions StandardsThis product meets the following standards.RFI Emissions FCC Class A, CE EN61000-4-2, CE EN61000-4-3, CE EN-

Pagina 26 - 4.3 Dual Homing Application

26 AT-IFS802SP-80 User Manual1. Launch the Internet Explorer on the PC2. Key in “http:// “+” the IP address of the switch”, and then Press “Enter”.C

Pagina 27 - Chapter 5 Console Management

27AT-IFS802SP-80 User Manual3. The login screen will appear right after4.Keyintheusernameandpassword.Thedefaultusernameandpasswordare

Pagina 28 - 5.4 CLI Management

28 AT-IFS802SP-80 User Manual6.5IPCongurationTheswitchisanetworkdevicewhichneedstobeassignedanIPaddressforbeingidentiedonthene

Pagina 29 - 5.5 Commands Level

29AT-IFS802SP-80 User Manual6.6 DHCP ServerDHCPistheabbreviationofDynamicHostCongurationProtocolthatisaprotocolforassigningdynamic IP

Pagina 30 - 6.3 System Login

30 AT-IFS802SP-80 User Manual6.6.2 Client EntriesWhen the DHCP server function is enabled, the system will collect the DHCP client information

Pagina 31 - 6.4 System Information

31AT-IFS802SP-80 User Manual6.7 TFTPItprovidesthefunctionsallowingtheusertoupdatetheswitchrmwareviatheTrivialFileTransferProtocol(

Pagina 32 - A p p l y

32 AT-IFS802SP-80 User ManualBackupCongurationinterfaceYoucanbackupthecurrentcongurationfromashROMtotheTFTPserverforthepurposeof

Pagina 33

33AT-IFS802SP-80 User ManualSyslogCongurationinterfaceSimpleMailTransferProtocol(SMTP)isthestandardforemailtransmissionsacrossthenetwo

Pagina 34 - 6.6.3 Port and IP Bindings

34 AT-IFS802SP-80 User ManualSMTPCongurationinterfaceHaving ticked the Syslog/SMTP checkboxes, the event log/email alert will be sent to the system

Pagina 35

35AT-IFS802SP-80 User ManualPort event selection• : Also, before the drop-down menu items are available, the Syslog Client Modeselectionitemonthe

Pagina 37

36 AT-IFS802SP-80 User Manual6.9 Fault Relay AlarmThe Fault Relay Alarm function provides the Power Failure and Port Link Down/Broken detection. With

Pagina 38

37AT-IFS802SP-80 User ManualSNTP Client• : Enable/disable SNTP function to get the time from the SNTP server.Daylight Saving Time• : This is used as

Pagina 39

38 AT-IFS802SP-80 User ManualSNTP Sever URL• :SettheSNTPserverIPaddress.YoucanassignalocalnetworktimeserverIPaddress or an internet t

Pagina 40 - 6.10SNTPConguration

39AT-IFS802SP-80 User Manual6.11 IP SecurityIPsecurityfunctionallowstheusertoassign10specicIPaddressesthathavepermissiontomanagethe

Pagina 41

40 AT-IFS802SP-80 User Manual6.12 User AuthenticationChange web management login user name and password for the management security issue.User name•

Pagina 42

41AT-IFS802SP-80 User ManualPort Statistics interface6.14 Port ControlInPortcontrolyoucancongurethesettingsofeachporttocontroltheconne

Pagina 43

42 AT-IFS802SP-80 User ManualPort Control interface6.15 Port TrunkPort trunking is the combination of several ports or network cables to expand the c

Pagina 44

43AT-IFS802SP-80 User ManualWork ports• :Thiscolumneldallowstheusertotypeinthetotalnumberofactiveportupto four. With LACP static tr

Pagina 45

44 AT-IFS802SP-80 User ManualLACP disabled•Having set up the aggregator setting with LACP disabled, you will see the local static trunk group inf

Pagina 46 - 6.15 Port Trunk

45AT-IFS802SP-80 User ManualAssigning 2 ports to a trunk group with LACP disabledStatic Trunking Group informationLACP enabled•Having set up the

Pagina 47 - D e l e t e

5PrefaceThis manual is the installation and management guide for the AT-IFS802SP 8x10/100TX POE Layer 2 Managed Industrial Switch. The instructions in

Pagina 48

46 AT-IFS802SP-80 User ManualSwitch2congurationSwitch2congurationinterface1. Set System Priority of the trunk group. The default is 1.2. Sele

Pagina 49

47AT-IFS802SP-80 User ManualHavingsetuptheLACPaggregatoronthetabofAggregatorSetting,youcancongurethestateactivityforthemembersof

Pagina 50

48 AT-IFS802SP-80 User Manual6.16 Port MirroringThePortmirroringisamethodformonitortrafcinswitchednetworks.Trafcthroughportscanbem

Pagina 51

49AT-IFS802SP-80 User Manual6.17 Rate LimitingYoucansetupeveryport’sbandwidthrateandframelimitationtype.Ingress Limit Frame type• :selec

Pagina 52

50 AT-IFS802SP-80 User Manual6.18VLANcongurationA Virtual LAN (VLAN) is a logical network grouping that limits the broadcast domain, which would a

Pagina 53

51AT-IFS802SP-80 User ManualPull down the selection item and focus on • Port Based then press to set the VLAN Operation Mode in Port Base

Pagina 54 - 6.18VLANconguration

52 AT-IFS802SP-80 User ManualVLAN—Port Based Edit/Delete interfaceUse to delete the VLAN.•Use to modify group name, VLAN ID, or a

Pagina 55

53AT-IFS802SP-80 User ManualPull down the selection item and focus on • 802.1Q then press to set the VLAN Operation Mode in 802.1Q mode.Enable GVRP

Pagina 56

54 AT-IFS802SP-80 User ManualHybrid Link: A segment which consists of Access and Trunk links. The hybrid port has both the features of access and tr

Pagina 57 - 802.1QConguration

55AT-IFS802SP-80 User ManualGroupCongurationinterface> Click .A p p l y6.19 Rapid Spanning TreeThe Rapid Spanning Tree Protocol (RST

Pagina 58

Preface6

Pagina 59

56 AT-IFS802SP-80 User Manual[note]FollowtheruleasbelowtoconguretheMAXAge,HelloTime,andForwardDelay Time.2 x (Forward Delay Time value

Pagina 60

57AT-IFS802SP-80 User ManualRSTPPortCongurationinterface6.20SNMPCongurationSimple Network Management Protocol (SNMP) is the protocol developed

Pagina 61 - R e m o ve

58 AT-IFS802SP-80 User ManualAgent Mode• : Select the SNMP version that you want to use it. And then click to switch to the selected SNMP v

Pagina 62 - C h a n g e

59AT-IFS802SP-80 User ManualConguretheSNMPV3function.Context TableCongureSNMPv3contexttable.Assignthecontextnameofcontexttable.Click

Pagina 63 - 6.20.3SNMPV3Conguration

60 AT-IFS802SP-80 User ManualAccess TableCongureSNMPv3accesstable.ContextPrex• : set up the context name.Group Name• : set up the group.Secur

Pagina 64

61AT-IFS802SP-80 User ManualUse a strict priority scheme:Alwaysthehigherqueuewillbeprocessedrst,exceptthehigher queue is empty.Priority Ty

Pagina 65

62 AT-IFS802SP-80 User ManualSet up the COS priority level. With the drop-down selection item of Priority Type above being selectedasCOSonly/COSr

Pagina 66

63AT-IFS802SP-80 User ManualThe switch support IP multicast, you can enable IGMP protocol on web management’s switch setting advanced page, then the I

Pagina 67

64 AT-IFS802SP-80 User ManualEnable Ring• : To enable the X-Ring function, tick the checkbox beside the Enable Ring string label. If this checkbox is

Pagina 68

65AT-IFS802SP-80 User Manual6.24LLDPCongurationLinkLayerDiscoveryProtocol(LLDP)isdenedintheIEEE802.1AB,itisanemergingstandardwhic

Pagina 69

3AT-IFS802SP-80 User ManualContentChapter 1 Introduction ... 61.1 Hardware Fea

Pagina 70

66 AT-IFS802SP-80 User Manual802.1xSystemCongurationinterfaceYoucancongurethe802.1xauthenticationstateforeachport.ThestateprovidesDi

Pagina 71

67AT-IFS802SP-80 User ManualQuiet Period:• Set the period which the port doesn’t try to acquire a supplicant.TX Period• : Set the period port

Pagina 72

68 AT-IFS802SP-80 User ManualAdd the Static MAC AddressYoucanaddstaticMACaddressintheswitchMACtablehere.MAC Address• :EntertheMACaddre

Pagina 73 - Clear MA C Table

69AT-IFS802SP-80 User ManualMAC Address• :EntertheMACaddressthatyouwanttolter.Click .•IfyouwanttodeletetheMACaddressfromt

Pagina 74 - Multicast Filtering interface

70 AT-IFS802SP-80 User ManualMulticast Filtering interface

Pagina 75 - 6.29 System Reboot

71AT-IFS802SP-80 User Manual6.27 Factory DefaultResetswitchtodefaultconguration.Clicktoresetallcongurationstothedefaultva

Pagina 76 - Troubles shooting

72 AT-IFS802SP-80 User ManualTroubles shootingVerify that is using the right power cord/adapter (DC 24-48V), please don’t use the power adapter •with

Pagina 77

73AT-IFS802SP-80 User ManualAppendix A—RJ-45 Pin AssignmentRJ-45 Pin AssignmentsThe UTP/STP ports will automatically sense for Fast Ethernet (10Base-T

Pagina 78

74 AT-IFS802SP-80 User Manual10/100Base-TX Cable Schematic•Thefollowingtwoguresshowthe10/100Base-TXcableschematic.Straight-through cable sch

Pagina 79 - Cross over cables schematic

75AT-IFS802SP-80 User Manual10/100/1000Base-TX Cable Schematic•Straight through cables schematicCross over cables schematic

Pagina 80 - Appendix B—Command Sets

4 AT-IFS802SP-80 User Manual6.9 Fault Relay Alarm ...

Pagina 81

76 AT-IFS802SP-80 User ManualAppendix B—Command SetsCommands Set ListUser EXEC Privileged EXEC Globalconguration   VLAN database

Pagina 82 - Port Commands Set

77AT-IFS802SP-80 User Manualadmin password[Password]GSpeciesapassword(maximum 10 words)switch(cong)#adminpasswordxxxxxxshow admin PShow adminis

Pagina 83

78 AT-IFS802SP-80 User ManualPort Commands SetNetstar Commands Level Description Exampleinterface fastEthernet [Portid] GChoose the port for modicati

Pagina 84 - Trunk Commands Set

79AT-IFS802SP-80 User Manualbandwidth out [Value]Set interface output bandwidth. Rate Range is from 100 kbps to 102400 kbps or to 256000 kbps for giga

Pagina 85 - VLAN Commands Set

80 AT-IFS802SP-80 User ManualTrunk Commands SetNetstar Commands Level Description Exampleaggregator priority[1~65535]GSet port group system prioritysw

Pagina 86

81AT-IFS802SP-80 User ManualVLAN Commands SetNetstar Commands Level Description Examplevlan database P EnterVLANconguremode switch#vlan databaseVl

Pagina 87 - Spanning Tree Commands Set

82 AT-IFS802SP-80 User Manualvlan 8021q trunk[PortNumber]access-link untag[UntaggedVID]VAssign a access link for VLAN by trunk groupswitch(vlan)#vlan

Pagina 88

83AT-IFS802SP-80 User ManualSpanning Tree Commands SetNetstar Commands Level Description Examplespanning-tree enable G Enable spanning tree switch(con

Pagina 89 - Commands Set

84 AT-IFS802SP-80 User Manualstp-path-priority[Port Priority] IUse the spanning-tree port-priority interface congurationcommandtocongureaportp

Pagina 90

85AT-IFS802SP-80 User Manual Commands SetNetstar Commands Level Description Exampleqos policy[weighted-fair|strict]GSelect QOS policy schedulingswitch

Pagina 91

5AT-IFS802SP-80 User ManualVLAN Commands Set ...

Pagina 92

86 AT-IFS802SP-80 User ManualIGMP Commands SetNetstar Commands Level Description Exampleigmp enable GEnable IGMP snooping functionswitch(cong)#igmpe

Pagina 93

87AT-IFS802SP-80 User ManualMac / Filter Table Commands SetNetstar Commands Level Description Examplemac-address-table static hwaddr [MAC]ICongureMA

Pagina 94

88 AT-IFS802SP-80 User ManualSNMP Commands SetNetstar Commands Level Description Examplesnmp system-name [System Name]GSet SNMP agent system nameswitc

Pagina 95

89AT-IFS802SP-80 User Manualsnmpv3 mibview view [View Name] type [Excluded|Included] sub-oid [OID]GCongurethemibviewtableof SNMPV3 agentswitch(co

Pagina 96

90 AT-IFS802SP-80 User ManualPort Mirroring Commands SetNetstar Commands Level Description Examplemonitor [RX|TX|Both]IConguresourceportofmonitor

Pagina 97

91AT-IFS802SP-80 User Manual802.1x Commands SetNetstar Commands Level Description Example8021x enable GUse the 802.1x global congurationcommandtoe

Pagina 98

92 AT-IFS802SP-80 User Manual8021x misc maxrequest [number]GUse the 802.1x misc max requestglobalcongurationcommand to set the MAX requests.switch

Pagina 99

93AT-IFS802SP-80 User ManualTFTP Commands SetNetstar Commands Level Description Examplebackupash:backup_cfgGSavecongurationtoTFTPand need to spe

Pagina 100 - SNTP Commands Set

94 AT-IFS802SP-80 User ManualSystemLog, SMTP and Event Commands SetNetstar Commands Level Description Examplesystemlog ip [IP address]GSet System log

Pagina 101 - X-ring Commands Set

95AT-IFS802SP-80 User Manualno event authentication-failureGDisable Authentication failure event typswitch(cong)#noeventauthentication-failureno ev

Comentarios a estos manuales

Sin comentarios