191
LeaveTime - This parameter is the GARP Leave Timer. Its range
is 30 - 2147483630 milli-seconds. This timer must be set in relation
to the GVRP Join Timer according to the following equation:
GARPLeaveTimer >= (GARPJoinTimer X 2) + 10
LeaveAllTime - This parameter is the GARP Leave Timer. Its
range is 30 - 2147483630 milli-seconds. This timer must be set in
relation to the GVRP Leave Timer according to the following
equation:
GARPLeaveAllTimer > (GARPLeaveTimer + 10)
Note
To ensure compatibility between network devices, you must
configure the same values for the GARP Join Timer, GARP Leave
Timer, and GARP Leave All Timer on all participating GVRP devices
in your network.
5. Once you have configured the parameters, click Apply for the affected
port.
6. If you want to configure the GVRP timers for other ports, repeat Step 4
and Step 5.
7. From the main menu on the left side of the page, select Save Settings
to Flash to permanently save your changes.