AlliedWare Plus Version 2.1.8 Management Software Web Interface User’s Guide
191
exchange with a client. The range is 1
to 65,535 seconds. The default value is
60 seconds.
Tx-period Sets the number of seconds an
authenticator port waits for a response
to an EAP-request/identity frame from
a client before retransmitting the
request. The default value is 30
seconds. The range is 1 to 65,535
seconds.
Reauth-period Specifies the time interval that an
authenticator port requires a client to
reauthenticate. The range is 1 to
65,535 seconds. The default value is
3600 seconds.
Supplicant-timeout Sets the timer used by the switch to
determine authentication server
timeout conditions. The range is 1 to
65,535 seconds. The default value is
30 seconds.
Server-timeout Sets the timer used by the switch to
determine authentication server
timeout conditions. The range is 1 to
65,535 seconds. The default value is
30 seconds.
Re-authentication— Activates reauthentication on the
authenticator port. The client must periodically reauthenticate
according to the time interval set with the Reauth-period timer.
Click the box to activate this field.
Number of Re-auth Requests— Specifies the maximum number
of times the switch retransmits EAP Request packets to a client
before it times out an authentication session. The range is 1 to 10
retransmissions. The default value is 2.
Port Control Direction— Specifies whether authenticator ports
that are in the unauthorized state should forward egress broadcast
and multicast traffic. Choose from the following:
In Specifies that authenticator ports in the
unauthorized state should forward egress
broadcast and multicast traffic, and discard the
ingress broadcast and multicast traffic. This is
the default setting.
Vista de pagina 190
1 2 ... 186 187 188 189 190 191 192 193 194 195 196 ... 257 258

Comentarios a estos manuales

Sin comentarios