Allied-telesis AT-IX5-28GPX Manual de usuario Pagina 128

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 129
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 127
Appendix A: Technical Specifications
128
Fiber Optic Specifications of the AT-StackOP/0.3 and AT-StackOP/9.0
Transceivers
Table 16 lists the fiber optic port specifications for the AT-StackOP/0.3
transceiver.
Table 16. Fiber Optic Port Specifications for the AT-StackOP/0.3 Module
General
Maximum Distances 33 m with 62.5/125 µm (core/
cladding) multimode fiber optic
cable
300 m with 50/125 µm (core/
cladding) multimode fiber optic
cable
Fiber Optic Cable 50/125 µm or 62.5/125 µm (core/
cladding) multimode fiber optic
cable
Transmitter
Wavelength 850 nm
Output Optical Power -7.3 dBm min.
Receiver
Wavelength 850 nm
Maximum Sensitivity -9.9 dBm
Maximum Input Power -1 dBm
Vista de pagina 127
1 2 ... 123 124 125 126 127 128 129

Comentarios a estos manuales

Sin comentarios