The variable n is the current value of the Stack ID parameter in the display. For example, if
the current value of the parameter is 1, the command would be:
set stack moduleid=1 newmoduleid=auto
4. After entering the command, you need to reset the switch with this command because your
change to the switch’s ID assignment does not take affect until the unit is reset:
restart reboot
5. After the switch has completed the reset, log on again as the manager.
6. Enter this command again:
show stack
7. Verify that the Stack Mode is now AUTO. If it is, then you are finished updating the stand-
alone switch. If it is still STATIC, try repeating the command in step 3 and reset the unit.
Upgrading AT-9400 Stacks
The switches of a stack have to be upgraded as stand-alone units. This requires removing the
stacking cables from the switches. (In future releases, you’ll be able to use the new MODULE
parameter in the LOAD command and update the switches all at the same time.) To upgrade the
management software on the switches of a stack:
1. Start a local or remote management session on the master switch of the stack.
2. Enter the SAVE CONFIGURATION command to save the stack’s current configuration.
3. Enter LOGOUT to end the management session.
4. Power off the switches of the stack.
5. Disconnect the stacking cables from the AT-StackXG Modules.
6. Power on one of the switches and establish a local management session.
7. Download the new management software using XMODEM or TFTP. The command to
download the new software with XMODEM is:
load method=xmodem destfile=appblock
For instructions on how to download the new software using TFTP, refer to the AT-S63
documentation set.
8. After upgrading the management software on the switch, end the management session and
power off the switch.
9. Repeat steps 6, 7, and 8 on each of the switches in the stack.
10. After upgrading all the stack units, reconnect the stacking cables to the AT-StackXG
Modules.
11. Power on the switches. The switches can be powered on in any order.
Note:
All the switches in a stack must use the same version of the AT-S63 Management Software.
Otherwise, the stack may not successfully form and/or experience performance problems.