The following table lists the line card status LEDs.
Features
The AT-CV10x Series line cards are designed to support Link Test,
MissingLink™ (ML), Smart MissingLink (SML), and Auto-MDI/MDIX features.
The DIP switches are used to set these features.
DIP Switches
The AT-CV10x Series line card features two DIP switches, Diagnostic Mode
DIP Switch 1 (Table 1) and Port Configuration DIP Switch 2 (Table 2), as
shown in Figure 2.
The tables below list the positions of these two DIP switches.
LED Color Description
RDY Green The line card has passed diagnostics.
OFF The line card has not passed diagnostics.
SML Green The Smart MissingLink mode is enabled.
OFF The Smart MissingLink mode is disabled.
ML Green The MissingLink mode is enabled.
OFF The MissingLink mode is disabled.
Table 1. Diagnostic Mode DIP Switch 1 Positions
Operating Mode DIP 1 DIP 2 DIP 3 DIP 4
Link Test (default) OFF OFF X X
Smart MissingLink (SML) OFF ON XX
MissingLink™ (ML) ON OFF X X
Manufacturing Settings OFF OFF OFF OFF
“X” means the DIP switch position could be either ON or OFF.
Table 2. Port Configuration DIP Switch 2 Positions
Operating Mode DIP 1 DIP 2 DIP 3 DIP 4
Auto MDI-X Enabled (default) X ON XX
Auto MDI-X Disabled X OFF X X
Manufacturing Settings OFF OFF OFF OFF
“X” means the DIP switch position could be either ON or OFF.
Installing an AT-CV10x Series Line Card
Note
The Converteon™ line cards can be installed in any of the line card slots
located on the front panel of the Converteon™ chassis.
To install an AT-CV10x Series line card, perform the following procedure:
Caution
Before installing an AT-CV10x Series line card, refer to the appropriate
Converteon™ Series Chassis Installation Guide for electrical safety and
emission information.
Caution
Be sure to observe all standard electrostatic discharge (ESD)
precautions, such as wearing an antistatic wrist strap, to avoid
damaging the device. A line card can be damaged by static electricity.
1. Remove the Converteon™ line card from its shipping package and store
the package in a safe place.
You must use the original package if you need to return the unit to Allied
Telesis.
2. Select an empty line card slot in the Converteon™ chassis for the card.
3. Remove the AT-CV5PNL1 blank slot cover from the selected slot.
Keep the blank slot cover in a safe area in case you remove the line card.
The blank slot cover is used to keep dust from getting into the chassis and
maintains proper airflow, cooling, and ventilation throughout the chassis.
4. Locate the alignment guides in the chassis slot.
5. Align the back edge of the line card with the alignment guides located
inside the slot. Avoid touching the line card components.
– For the AT-CV5000, align with the top and bottom alignment guides.
– For the AT-CV1000 and AT-CV1200, align with the left and right
alignment guides.
6. Slide the line card until the front of the card is flushed with the front of the
chassis.
7. Use a Phillips screwdriver to tighten the captive screw on the line card.
8. Repeat this procedure to install additional line cards.
Cabling an AT-CV10x Series Line Card
To connect the cables to an AT-CV10x Series line card, refer to the
Converteon™ Media Converter Line Cards Reference Guide for instructions.
Technical Specifications
Physical, Environmental, and Electrical Rating
Dimensions (H x W x L) .855" x 2.89" x 5.1"
(2.2 cm x 7.3 cm x 13.0cm)
Operating Temperature 0° C to 40° C (32° F to 104° F)
Storage Temperature -25° C to 70° C (-13° F to 158° F)
Operating Relative Humidity 5% to 90% RH (non-condensing)
Storage Relative Humidity 5% to 95% RH (non-condensing)
Operating Altitude Range Up to 3,048 m (10,000 ft)
MTBF (Telcordia Standards)
AT-CV101 1,020,00 hrs
AT-CV102 890,000 hrs
AT-CV102/1, AT-CV102/2 1,020,00 hrs
Power Consumption
AT-CV101, AT-CV102 3.0 watts
AT-CV102/1 2.5 watts
AT-CV102/2 5.0 watts
Optical Specifications
Connector Type Dual SC or Dual ST
Wavelength (nm) 1310 nm or 1510 nm
Fiber Type Single-mode or Multi-mode
Operating Distance (km) 2 km (1.24 miles) to 40 km (24.8 miles)
Optical Output Power (dBm)
AT-CV101, AT-CV102 -20 dBm to -14 dBm
AT-CV102/1 -15 dBm to -5 dBm
AT-CV102/2 -15 dBm to 0 dBm
Receiver Power Sensitivity (dBm)
AT-CV101, AT-CV102 -31 dBm to -11 dBm
AT-CV102/1, AT-CV102/2 -34 dBm to -3 dBm
Electrical Safety and Emission Statement
Standards: This product meets the following standards when installed in compliant host equipment.
Emission FCC Class A, EN55022 Class A, VCCI Class A, C-TICK, CE
WARNING: In a domestic environment this product may cause radio interference in which
case the user may be required to take adequate measures.
Immunity EN55024
Electrical Safety UL60950-1 (
c
UL
us
), EN60950-1 (TUV), CAN/CSA C22.2 No. 60950-1
Copyright 2006 Allied Telesis, Inc. All rights reserved.
No part of this publication may be reproduced without prior written permission from Allied Telesis Inc.
U.S. Federal Communications Commission
RADIATED ENERGY
Note: This equipment has been tested and found to comply with the limits for a Class A digital device pursuant
to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This equipment generates, uses,
and can radiate radio frequency energy and, if not installed and used in accordance with this instruction
manual, may cause harmful interference to radio communications. Operation of this equipment in a residential
area is likely to cause harmful interference in which case the user will be required to correct the interference at
his own expense.
Note: Modifications or changes not expressly approved of by the manufacturer or the FCC, can void your right
to operate this equipment.
Industry Canada
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment
Regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur
du Canada.