Configuring LLDP
Page 181
Defining Global LLDP Properties
The LLDP Properties Page allows network managers to assign global LLDP parameters.
To enable and configure LLDP on the device:
1. Click LLDP > Properties. The LLDP Properties Page opens:
Figure 125:LLDP Properties Page
The LLDP Properties Page contains fields for configuring LLDP:
• Enable LLDP — Indicates if LLDP is enabled on the device. The possible field values are:
– Checked —Enables LLDP on the device. This is the default value.
– Unchecked — Disables LLDP on the device.
• Updates Interval (5 - 32768) — Indicates the interval (sec) between consecutive LLDP advertisement
updates The possible field range is 5 - 32768 seconds. The default value is 30 seconds.
– Use Default — Selecting the check box returns settings to default.
• Hold Multiplier (2 - 10) — Indicates the amount of time that LLDP packets are held by a receiving device
before the packets are discarded. The value represents a multiple of the Updates Interval. The possible field
range is 2 - 10. The field default is 4. For example, if the Update Interval is 30 seconds and the Hold Multiplier
is 4, then the LLDP packets are discarded after 120 seconds.
– Use Default — Selecting the check box returns settings to default.
• Reinitializing Delay (1 - 10) — Indicates the amount of time an LLDP port waits before reinitializing LLDP
transmissions. The possible field range is 1 - 10 seconds. The default value is 2 seconds.
– Use Default — Selecting the check box returns settings to default.