Allied-telesis AT-MC1005/4 Manual de usuario Pagina 20

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 44
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 19
Installing the Media Converter
10
Table 3 Twisted Pair Cabling Specifications
Note
The 1000Base-T ports use 4 pair (8 wires) in a twisted pair cable.
Table 4 Fiber Optic Cabling Specifications
Selecting a Site
Be sure to observe the following requirements when choosing a site for your
media converter.
Select a site that is dust-free and moisture-free.
Be sure that the site will allow you to easily access the fiber optic and
twisted pair cables and the power cord.
Use dedicated power circuits or power conditioners to supply reliable
power to the device.
Model Cable Maximum Operating
Distance
All Models Shielded Twisted Pair Category 5
or better
100 m (328 ft)
Model Cable Maximum
Operating
Distance
Maximum
Allowable Loss
Budget
AT-MC1004 50/125 micron multimode 550 m (1,804 ft) 8.5 dB at 850 nm
62.5/125 micron
multimode
1
1. Based on the multi-mode fiber cable with 200MHz per kilometer on the modal bandwidth @ 850 nm.
275 m (902 ft) 7.5 dB at 850 nm
AT-MC1005/1 9/125 micron single-mode 10 km (6.2 mi) 17.0 dB at 1310 nm
AT-MC1005/2 9/125 micron single-mode 20 km (12.4 mi) 18.0 dB at 1310 nm
AT-MC1005/3 9/125 micron single-mode
2
2. For maximum performance of Gigabit Optical Datalinks when greater than 40 km (24.8 mi) and operating within the
1550 nm optical spectrum, it is mandatory that the Single-mode Fiber (SMF) be rated as non-dispersion-shifted,
dispersion shifted, or non-zero dispersion shifted.
40 km (24.8 mi) 18.0 dB at 1550 nm
AT-MC1005/4 9/125 micron single-mode
2
70 km (43.4 mi) 20.0 dB at 1550 nm
Vista de pagina 19
1 2 ... 15 16 17 18 19 20 21 22 23 24 25 ... 43 44

Comentarios a estos manuales

Sin comentarios