AT-EN646MOD Installation Guide
20 Chapter 3: Enclosure Installation
Secure the Tracer Wire and Aramid Yarn
Note
Any tracer wire or cable armoring on the fiber optic drop cable must be connected to the grounding
plate.
Follow the procedure below to secure the drop cable tracer wire.
To secure the drop cable tracer wire and aramid yarn, perform the following procedure:
1. Cut the tracer wire to 2.5 in. (7 cm) from the grommet.
2. Remove the nut on the tracer wire post.
3. Use a ring lug (26-22 AWG, #10 stud size) to secure the tracer wire to the post.
4. Re-attach the nut removed in Step 2 and tighten on the ring lug, as shown in Figure 13.
Figure 13. Securing the Tracer Wire and Aramid Yarn