7.1 RMON-specific Buttons
The RMON window is slightly different from the MIB variable windows. The RMON
window has several tabs and each tab has the following tool buttons in addition to the
buttons in the MIB variable windows.
Absolute Value
Displays collected data as they are.
Per Sample
Displays the difference between the last two sampled values. The value is rounded.
Per Second
Displays the difference between the last two sampled values per second.
This is (Current value - Previous value) / Polling Interval. The value is rounded.
Start Polling
Restarts polling.
Stop Polling
Pauses polling. This may be useful for examining current data carefully.
Refresh
Forces immediate polling and displays the latest sampled value regardless of the
regular polling timer.